A PV panel driving an electrical device (load) that has a constant-total-resistance is considered here. The main
object of the study is to determine optimal value of the resistance to adjust volt-amper characteristics of the load
to those that provides maximum power output for PV panel. A simple mathematical approach is proposed here
for this purpose. The other significant part of the study is introducing a handy method to consider hourly solar
radiation utility potential of any location on every day of the year for testing the optimization. A particular
numerical example performed for Sanliurfa province has shown that solar radiation intensity of 500 W/m2 or
above is high enough to design a PV system in this location to reach maximum utilization of the system.

Downloads

Download data is not yet available.

References

[1] Muntasser, M.A., Bara, M.F., Quadri, H.A., ELTarabelsi,
R., La-azebi, I.F., “Photovoltaic Marketing
İn Developing Countries”, Applied Energy, Vol. 65,
pp. 67-72, 2000.
[2] Kurokawa, K., Ikki, O., “The Japanese
Experiences with National PV System Programmes”,
Solar Energy, Vol. 70, pp. 457-466, 2001.
[3] Oliver, M., Jackson, T., “The Market for Solar
Photovoltaics”, Energy Policy, Vol. 27, pp. 371-385,
1999.
[4] Yeşilata, B., Aktacir, M.A., “ Fotovoltaik Güç
Sistemli Su Pompalarının DizaynEsaslarının
Araştırılması”, Mühendis ve Makine, cilt 42, sayı.
493, sy. 29-34, 2000.
[5] Lin, G. H., Carlson, D.E., “Photovoltaics in the
year 2025”, Hydrogen Energy, Vol. 25, pp. 807-811,
2000.
[6] Yeşilata,B., Fıratoğlu, Z., A., “Bataryalı ve Direkt
Akupleli Fotovoltaik Pompa Sistemlerinin Çalışma
Karakteristiklerinin Araştırılması”, Yenilenebilir
Enerji Kaynakları Sempozyumu, 10-12 Eylül 2001,
Kayseri.
[7] Fraidenraicch, N., Vilela, O., C., “ Performance
of Solar systems with Non-Linear Behavior calculated
by the Utilizability method: Application to PV Solar
Pompa”, Solar Energy, Vol. 69 pp. 131-137, 2000.
[8] Appelbaum, J., “Performance Analysis of DC
Motor-Photovoltaic Converter System-II”, Solar
Energy, Vol. 27, pp. 421-431, 1981.
[9] Suehrcke, H., Appelbaum, J., Reshef, B.,
“Modelling a Permanent DC Motor / Centrrifugal
Pump Assembly in a Photovoltaic Energy System”,
Solar Energy, Vol. 99, pp. 37-42, 1997.
[10] Fıratoğlu, Z., A., Yeşilata,Bülent, “Fotovoltaik
Destekli Su Pompası Uygulamasının Dinamik
Analizi”, II Gap ve Sanayi Kongresi Bildiriler Kitabı,
29-30 Eylül 2001, Diyarbakır.
[11] Kou, Q., Kleın, A., Beckman, W., “ A Method
for Estımatıng the Long-Term Performance of Dırect-
Coupled PV Pumpıng Systems”, Solar Enery, Vol. 64,
pp.33-40, 1998.
[12] Kou, Q., "A Method for Estimation the Long
Term Performance of Photovoltaic Pumping
System.", Master Thesis, The University of
Wisconsion-Madison, Solar Energy Laboratury, 1996.
[13] Fıratoğlu, Z. A., Yeşilata, B., “Maksimum Güç
Noktası İzleyicili Fotovoltaik Sistemlerin Optimum
Dizayn ve Çalışma Koşullarının Araştırılması”, 6-
Türk-Alman Enerji Sempozyumu Bildiriler Kitabı, 20-
23, Temmuz 2001.
[14] Fıratoğlu, Z., A., Yeşilata, Bülent, “Fotovoltaik
Güç Destekli Dalgıç Pompa Sistemlerinde Optimum
Dizayn Koşullarının Araştırılması”, Tesisat
Mühendisliği Dergisi, Nisan-Mart 2001, Sayfa:59-66.
[15] Hsieh S.J., Solar Energy Engineering, Prentice-
Hall, Inc, Englewood Cliffs, New Jersey, 1986.
[16] Bloos, H., “ Analytical and Exerimental
İnvestigation of Photovoltaic Pumping Systems”,
Doctor Thesis, University of Oldenburg, 2000.

Published

27-01-2003

How to Cite

[1]
Z. A. Fıratoğlu and B. Yeşilata, “LİNEER ELEKTRİKSEL YÜKE BAĞLI PV PANELLERİN OPTİMİZASYONU VE BÖLGESEL UYGULANABİLİRLİĞİNİN ARAŞTIRILMASI”, JAST, vol. 1, no. 1, pp. 65–72, Jan. 2003.

Issue

Section

Articles